used to prevent tonnage alarms from occurring, it will bypass ALL alarms (except machine rating
alarms). Instead, it is suggested that the High Limits and Reverse Limits active during the working
portion of the stroke (View: Peak Tonnage) be set for the approximate tonnage rating of the die. The
Low Limits will be automatically disabled in Inch
or Timed Inch modes.
After the correct tonnage monitor settings are established for the die, along all other OmniLink 5000
settings, the present settings should be stored under a job number and description for recall later.