April 12, 2012 Manual Version 1.1
6.5
shown if the position transducer is still functioning correctly.
Waiting for Cntr-Bal The slide adjust system is waiting for the counterbalance, if present, to come
to its correct pressure before automatically moving the slide.
Slide Too High The slide is higher than the slide setpoint plus tolerance.
Slide Too Low The slide is lower than the slide setpoint minus tolerance.
Hyd Overload Tripped The hydraulic overload has tripped. The slide will not move down in this
condition.
Auto-Adjusting The slide is automatically going to the programmed slide setpoint.
Waiting for Top The slide must be at the top of the stroke for automatic positioning to occur.
If a job is recalled at the bottom of the stroke, this message will be displayed
until the press is at the top.
E-Stop Button Emergency stop button is depressed. The slide will not automatically move in
this condition.
Waiting S/A Switch Waiting for the slide adjust switch to be turned on. The slide cannot move
while the slide adjust switch is in the off position.
LMC is Out The Link Master Control relay is disengaged for some reason (possibly an
error at the control). No slide movement may be made while the LMC is
tripped.