Link-systems LinkNet I Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Link-systems LinkNet I. LINK Systems LinkNet I User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 47
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
LinkNet
LinkNet
Pressroom
Monitorin
g
Software
Installation and Operatin
g
Manual
Vue de la page 0
1 2 3 4 5 6 ... 46 47

Résumé du contenu

Page 1 - Software

LinkNetLinkNetPressroomMonitoringSoftwareInstallation and OperatingManual

Page 2

LinkNet2.4 manual rev 2.1 March 25, 19992.3 System 1100 ConnectionsSystem 1100 tonnage monitors with softwareversions older than vers

Page 3

LinkNet2.5 manual rev 2.1 March 25, 1999Figure 2.4: Regular Drop Box ConnectorsFigure 2.5: Repeater Drop Box ConnectionsWhenever poss

Page 4

LinkNet2.6 manual rev 2.1 March 25, 1999The installation program will create a newprogram group called “LinkNet” and will put aLinkNe

Page 5

LinkNet3.1 manual rev 2.1 March 25, 19993. Configuration After the software is installed, it must beconfigured. This consists of the

Page 6

LinkNet3.2 manual rev 2.1 March 25, 1999Figure 3.3: Shift Configuration DialogEach day may have up to three shiftsconfigured. The “U

Page 7

LinkNet3.3 manual rev 2.1 March 25, 1999then be sent to each press on the networkautomatically. 3.3.1 Adding a Down Time CodeTo Add

Page 8

LinkNet3.4 manual rev 2.1 March 25, 1999Figure 3.6: Machine Configuration ListThis dialog allows machine to be added, edited,and dele

Page 9

LinkNet3.5 manual rev 2.1 March 25, 1999Note that the idle condition will be activatedONLY if a down time code is not alreadyentered

Page 10

LinkNet3.6 manual rev 2.1 March 25, 1999Figure 3.10: Die Configuration InformationEnter the machine number that this dieinformation a

Page 11

LinkNet3.7 manual rev 2.1 March 25, 19993.5.3 Deleting DiesTo delete a die, select it the list Figure 3.9 andhit the “Delete Die” but

Page 13

LinkNet3.8 manual rev 2.1 March 25, 1999engagements.PM can be set by machine or die. If set up bydie, the PM settings will be tracke

Page 14

LinkNet3.9 manual rev 2.1 March 25, 1999anything desired.Hit the “Add PM Item” button and the dialog offigure 3.15 should be displaye

Page 15

LinkNet3.10 manual rev 2.1 March 25, 19993.7.3 Resetting a Preventive Maintenance ItemWhen a PM has “tripped” (exceeded its limit), i

Page 16

LinkNet4.1 manual rev 2.1 March 25, 1999Figure 4.1: Example Pressroom Overview Window4. Using LinkNet4.1 The Overview WindowWhen Link

Page 17

LinkNet4.2 manual rev 2.1 March 25, 1999 minute poll is multiplied by the remaining parts tobe produced as given by the part counter

Page 18

LinkNet4.3 manual rev 2.1 March 25, 1999Tuesday.The average tonnage, highest good tonnage, andlowest good tonnage are collected in 10

Page 19

LinkNet4.4 manual rev 2.1 March 25, 19994.2.4 Tonnage DetailThe tonnage detail screen (“Peak Tons” tab - seeFigure 4.5) shows the ton

Page 20

LinkNet5.1 manual rev 2.1 March 25, 19995. ReportsThere are several reports that can be generatedfrom the data that LinkNet collects.

Page 21

LinkNet5.2 manual rev 2.1 March 25, 1999The event log is captured by day because of thelevel of detail. This allows for keeping only

Page 22

LinkNet5.3 manual rev 2.1 March 25, 1999through, exported, or printed from the tool buttonsat the top of the report window. The thre

Page 23

LinkNeti.1 manual rev 2.1 March 25, 1999Table of Contents1. Introduction...

Page 24

LinkNet5.4 manual rev 2.1 March 25, 1999The graph shows the average tonnage, highestgood tonnage, and lowest good tonnage which areco

Page 25

LinkNet5.5 manual rev 2.1 March 25, 1999Note that when a quick report is generated, itonly applies to the machine that was clicked on

Page 26

LinkNet6.1 manual rev 2.1 March 25, 1999No two machines may have the same machinenumber or a machine number of 0!6. Using the OmniLin

Page 27

LinkNet6.2 manual rev 2.1 March 25, 1999Note that the “NETWORK OPS” softkey andthe “Current DTC” message in the counterscreen will no

Page 28

LinkNet6.3 manual rev 2.1 March 25, 1999If a down time code is active, whether automaticor operator entered, a “CLEAR DTC” softkey wi

Page 29

LinkNet6.4 manual rev 2.1 March 25, 19996.5 Sending Tonnage Graphs from theOmniLink 5000LinkNet has the ability to receive and displa

Page 30

LinkNet6.5 manual rev 2.1 March 25, 1999notes above. Hit the “MACHINE NOTES”softkey to view the machine notes again.

Page 31

LinkNet7.1 manual rev 2.1 March 25, 1999No two machines may have the same machinenumber or a machine number of 0!Note that pressing t

Page 32

LinkNet7.2 manual rev 2.1 March 25, 1999When a user entered DTC (not an automaticDTC) is active, the bar graphs beside eachchannel bl

Page 33

LinkNet7.3 manual rev 2.1 March 25, 1999Note that the “NETWORK” menu will notappear if LinkNet is not running, if the System1100 ha

Page 34

LinkNeti.2 manual rev 2.1 March 25, 19995. Reports ...5.15.1 T

Page 35

LinkNet7.4 manual rev 2.1 March 25, 1999Use the up and down arrow keys to select“CLOCK” and hit the “ENTER” key.A screen with the cur

Page 36

LinkNetA.1 manual rev 2.1 March 25, 1999If the OIT software version is older thanversion 2.0, the OIT and motherboard softwareMUST bo

Page 37

LinkNetA.2 manual rev 2.1 March 25, 1999Figure A.1: System 1100 OIT Circuit BoardA.2.2 System 1100 Motherboard SoftwareUpgrade Proced

Page 38

LinkNetA.3 manual rev 2.1 March 25, 1999A.3 OmniLink 5000 Upgrade ProcedureMost OmniLink 5000 press controls shippedprior to July 199

Page 39

LinkNetA.4 manual rev 2.1 March 25, 1999Figure A.5:OIT to New CommunicationsBoard ConnectionsA.3.2 OmniLink OIT Software UpgradeProce

Page 40

LinkNetA.5 manual rev 2.1 March 25, 1999Note that communications cards can have upto two additional software chips as options (afeed

Page 41

LinkNetA.6 manual rev 2.1 March 25, 1999A.3.5 OmniLink Die Protection Module SoftwareUpgrade ProcedureThis upgrade procedure applies

Page 42

LinkNetA.7 manual rev 2.1 March 25, 1999A.3.7 OmniLink Auto-Setup Module SoftwareUpgrade ProcedureThis upgrade procedure applies only

Page 43

LinkNet1.1 manual rev 2.1 March 25, 19991. IntroductionThe Link Systems Network Application(LinkNet) provides detailed monitoring of

Page 44

LinkNet1.2 manual rev 2.1 March 25, 1999At least one free RS232 serial portRecommended Hardware:Pentium II 333MHz CPU or better32MB m

Page 45

LinkNet2.1 manual rev 2.1 March 25, 1999Figure 2.1: Daisy Chained Network Example2. InstallationLinkNet is connected to each piece of

Page 46

LinkNet2.2 manual rev 2.1 March 25, 1999At the computer, an RS232 to RS485 converteris necessary. This converts the standard serial

Page 47

LinkNet2.3 manual rev 2.1 March 25, 1999Belden 8103 cable and many similar cablesorganized as twisted pairs use a special color codes

Commentaires sur ces manuels