ERROR CODES
___________________________________________________________________
Error No. Message / Action
10-7
048 Channel 1 high setpoint too high.
049 Channel 2 high setpoint too high.
050 Channel 3 high setpoint too high.
051 Channel 4 high setpoint too high.
The Peak tonnage high setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1) Check the MACH RATING setting in the Config menu
for correctness.
2) Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
052 Channel 1 low setpoint too high.
053 Channel 2 low setpoint too high.
054 Channel 3 low setpoint too high.
055 Channel 4 low setpoint too high.
The Peak tonnage low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1) Check the MACH RATING setting in the Config menu
for correctness.
2) Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
056 Channel 1 reverse setpoint too high.
057 Channel 2 reverse setpoint too high.
058 Channel 3 reverse setpoint too high.
059 Channel 4 reverse setpoint too high.
The Peak tonnage reverse setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1) Check the MACH RATING setting in the Config menu
for correctness.
2) Adjust the indicated setpoint to a setting less